Price: 92,600 INR
Specifications:
Voltage Adj. Range 0 To 60V DC (Dual Output)
Current Range 0 To 20Adc (Dual Output)
Rated Power (1200W Each)
Metering & Control Separate Volt And Current Digital Display
Protection Overload Above 105% Rated Output Power
Protection Type: Constant Current, Recovers Automatically After Fault Condition Is Removed.
Over Voltage 125% - 150% Rated Output Voltage.
Protection Type: Hiccup Mode , Recovers Automatically After Fault Condition Is Removed.
Environment: Working Humidity 20 To 90% Rh non Condensing.
Storage Temp./Humidity (-10 To 85 Deg c 10 To 95% Rh )
Vibration (-10 To 500 Hz, 2G, 20Min / Sweep , Period - 1 Hr, Each Along X,Y,Z Axes.)
Safety Standard Designed To Meet Ul60950-1
With Stand Voltage I / P - O / P 2Kvdc , I / P- Earth, O / P-earth 2Kvdc
Isolation Resistance I / P - O / P , I / P- Earth, O / P-earth: 100Mohms / 500Vdc.
Emi & Emc Designed To Meet En55011 / En55022, En61000-4-2